 K4J55323QF-GC
256M GDDR3 SDRAM
256Mbit GDDR3 SDRAM
Revision 1.8 April 2005
INFORMATION IN THIS DOCUMENT IS PROVIDED IN RELATION TO SAMSUNG PRODUCTS, AND IS SUBJECT TO CHANGE WITHOUT NOTICE. NOTHING IN THIS DOCUMENT SHALL BE CONSTRUED AS GRANTING ANY LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IN SAMSUNG PRODUCTS OR TECHNOLOGY. ALL INFORMATION IN THIS DOCUMENT IS PROVIDED ON AS "AS IS" BASIS WITHOUT GUARANTEE OR WARRANTY OF ANY KIND.
1. For updates or additional information about Samsung products, contact your nearest Samsung office. 2. Samsung products are not intended for use in life support, critical care, medical, safety equipment, or similar applications where Product failure could result in loss of life or personal or physical harm, or any military or defense application, or any governmental procurement to which special terms or provisions may apply.
Samsung Electronics reserves the right to change products or specification without notice.
-1-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Revision History
Revision 1.8 (April 9, 2005)
- Modified note description for the Write Latency on page 47.
256M GDDR3 SDRAM
Revision 1.7 (Jan. 18 , 2005)
- Added Lead Free package part number in the data sheet.
Revision 1.6 (Dec 2 , 2004)
- Changed ICC2P and ICC6 for all frequency. Separted ICC6 for -GC and -GL.
Revision 1.5 (Oct 5 , 2004)
- Added K4J55323QF-G(V)C15 - Timing diagram corrected on page 28
Revision 1.4 (July 9 , 2004)
- Added K4J55323QF-G(V)L20 which is VDD&VDDQ=1.8V(typical)
Revision 1.3 (June 14 , 2004)
- Changed DC spec value for all the frequency. Refer to the DC characteristics of page 45. - Removed -GC12 from the spec.
Revision 1.2 (February 18 , 2004)
- Changed VDD/VDDQ from 1.9V+ 0.1V to 2.0V+ 0.1V in all frequencies. - DC changes : Refer to the DC characteristics of page 45.
Revision 1.1 (January 29 , 2004)
- Typo corrected
Revision 1.0 (January 15 , 2004)
- Changed VDD/VDDQ of K4J55323QF-GC12 from 2.1V+ 0.1V to 1.9V+ 0.1V - Changed VDD/VDDQ of K4J55323QF-GC14/16/20 from 1.8V+ 0.1V to 1.9V+ 0.1V - Changed tCK(max) from 3.0ns to 3.3ns - DC spec finalized. Typo corrected
-2-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Revision History
Revision 0.5 (January 7 , 2004) - Preliminary spec
- Added "Dummy MRS" command during the power-up sequence. Typo corrected
256M GDDR3 SDRAM
Revision 0.4 (December 10 , 2003) - Preliminary spec
- Typo corrected - Added K4J55323QF-GC12 (800MHz) in the spec - Key AC parameter changes : Refer to the AC spec table on page 46,47 . Added tDAL in the AC characteristics table, . Added AC parameter of -GC12 in the AC characteristics table, . Changed tRC of -GC14 from 31tCK to 30tCK, . Changed tRFC of -GC16 from 34tCK to 33tCK, - DC changes : Refer to the DC characteristics table of page 45. - Capacitance table change : Refer to the Capacitance table of page 45.
Revision 0.3 (November 13, 2003) - Target Spec
- Typo corrected - Removed 800MHz from the spec - Changed ICC6 from 4mA to 7mA - Key AC parameter changes : Refer to the AC spec table on page 46,47 . Changed tWR of -GC14 from 6tCK to 9tCK, . Changed tWR of -GC16 from 5tCK to 8tCK, . Changed tWR of -GC20 from 4tCK to 6tCK . Changed tPDEX and tXSR at low power from 100tCK to 300tCK
Revision 0.2 (October 17, 2003) - Target Spec
- Typo corrected
Revision 0.1 (September 26, 2003) - Target Spec
- Typo corrected
Revision 0.0 (September 25, 2003) - Target Spec
-3-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
256M GDDR3 SDRAM
2M x 32Bit x 4 Banks Graphic Double Data Rate 3 Synchronous DRAM with Uni-directional Data Strobe FEATURES
* 2.0V + 0.1V power supply for device operation * 2.0V + 0.1V power supply for I/O interface * On-Die Termination (ODT) * Output Driver Strength adjustment by EMRS * Calibrated output drive * Pseudo Open drain compatible inputs/outputs * 4 internal banks for concurrent operation * Differential clock inputs (CK and CK) * Commands entered on each positive CK edge * CAS latency : 5, 6, 7, 8 and 9 (clock) * Additive latency (AL): 0 and 1 (clock) * Programmable Burst length : 4 * Programmable Write latency : 1, 2, 3, 4, 5 and 6 (clock) * Single ended READ strobe (RDQS) per byte * Single ended WRITE strobe (WDQS) per byte * RDQS edge-aligned with data for READs * WDQS center-aligned with data for WRITEs * Data Mask(DM) for masking WRITE data * Auto & Self refresh mode * Auto Precharge option * 32ms, auto refresh (4K cycle) * 144 Ball FBGA * Maximum clock frequency up to700MHz * Maximum data rate up to 1.4Gbps/pin * DLL for outputs
ORDERING INFORMATION
Part NO. K4J55323QF-GC14 K4J55323QF-GC15 K4J55323QF-GC16 K4J55323QF-GC20* Max Freq. 700MHz 667MHz 600MHz 500MHz Max Data Rate 1400Mbps/pin 1334Mbps/pin 1200Mbps/pin 1000Mbps/pin Pseudo Open Drain 144 - Ball FBGA Interface Package
*K4J55323QF-GL20/VL20 : VDD & VDDQ = 1.8V+0.1V(1.7V ~ 1.9V) *K4J55323QF-V is the Lead Free package part number
GENERAL DESCRIPTION
FOR 2M x 32Bit x 4 Bank GDDR3 SDRAM
The 8Mx32 GDDR3 is 268,435,456 bits of hyper synchronous data rate Dynamic RAM organized as 4 x 2,097,152 words by 32 bits, fabricated with SAMSUNG's high performance CMOS technology. Synchronous features with Data Strobe allow extremely high performance up to 5.6GB/s/chip. I/O transactions are possible on both edges of the clock cycle. Range of operating frequencies, and programmable latencies allow the device to be useful for a variety of high performance memory system applications.
-4-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
PIN CONFIGURATION
Normal Package (Top View)
2 3 4
VSSQ VDDQ VSSQ VDD VDDQ VDDQ VDDQ VDDQ VDDQ VDD A10 A11
256M GDDR3 SDRAM
5
DQ3 VDDQ VSSQ VSS VSSQ VSSQ VSSQ VSSQ VSSQ VSS /RAS BA0
6
DQ2 DQ1 VSSQ VSSQ NC, VSS NC, VSS NC, VSS NC, VSS VSS RFU2 RESET /CAS
7
DQ0 VDDQ VDD VSS NC, VSS NC, VSS NC, VSS NC, VSS VSS VDD CKE CK
8
DQ31 VDDQ VDD VSS NC, VSS NC, VSS NC, VSS NC, VSS VSS VDD RFU5 /CK
9
DQ29 DQ30 VSSQ VSSQ NC, VSS NC, VSS NC, VSS NC, VSS VSS RFU1 ZQ /WE
10
DQ28 VDDQ VSSQ VSS VSSQ VSSQ VSSQ VSSQ VSSQ VSS /CS BA1
11
VSSQ VDDQ VSSQ VDD VDDQ VDDQ VDDQ VDDQ VDDQ VDD A9 A8/AP
12
13
B WDQS0 RDQS0 C D E F G
DQ4 DQ6 DQ7 DQ17 DQ19 DM0 DQ5 RFU3 DQ16 DQ18
RDQS3 WDQS3 DM3 DQ26 RFU4 DQ15 DQ13
RDQS1
DQ27 DQ25 DQ24 DQ14 DQ12
WDQS1
H WDQS2 RDQS2 J K L M N
DQ20 DQ21 DQ23 VREF A0 DM2 DQ22 A3 A2 A1
DM1 DQ9 A4 A5 A6
DQ11 DQ10 DQ8 VREF A7
NOTE : 1. RFU1 is reserved for A12 2. RFU2 is reserved for BA2 3. (M,13) VREF for CMD and ADDRESS 4. (M,2) VREF for Data input
-5-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
INPUT/OUTPUT FUNCTIONAL DESCRIPTION
Symbol CK, CK Type Input Function
256M GDDR3 SDRAM
Clock: CK and CK are differential clock inputs. CMD, ADD inputs are sampled on the crossing of the positive edge of CK and negative edge of CK. Output (read) data is referenced to the crossings of CK and CK (both directions of crossing). Clock Enable: CKE HIGH activates, and CKE Low deactivates, internal clock signals and device input buffers and output drivers. Taking CKE Low provides Precharge Power-Down and Self Refresh operation (all banks idle), or Active Power-Down (row Active in any bank). CKE is synchronous for power down entry and exit, and for self refresh entry. CKE is asynchronous for self refresh exit. CKE must be maintained high throughout read and write accesses. Input buffers, excluding CK, CK and CKE are disabled during powerdown. Input buffers, excluding CKE, are disabled during self refresh. Chip Select: All commands are masked when CS is registered HIGH. CS provides for external bank selection on systems with multiple banks. CS is considered part of the command code. Command Inputs: RAS, CAS and WE (along with CS) define the command being entered. Input Data Mask: DM is an input mask signal for write data. Input data is masked when DM is sampled HIGH coincident with that input data during a Write access. DM is sampled on both edges of clock. Although DM pins are input only, the DM loading matches the DQ and DQS loading. Bank Address Inputs: BA0 and BA1 define to which bank an Active, Read, Write or Precharge command is being applied. BA0 also determines if the mode register or extended mode register is to be accessed during a MRS or EMRS cycle. Address Inputs: Provided the row address for Active commands and the column address and Auto Precharge bit for Read/Write commands to select one location out of the memory array in the respective bank. A8 is sampled during a Precharge command to determine whether the Precharge applies to one bank (A8 LOW) or all banks (A8 HIGH). If only one bank is to be precharged, the bank is selected by BA0, BA1. The address inputs also provide the op-code during Mode Register Set commands. Row addresses : RA0 ~ RA11, Column addresses : CA0 ~ CA7, CA9 . Column address CA8 is used for auto precharge. Data Input/ Output: Bi-directional data bus. READ Data Strobe: Output with read data. RDQS is edge-aligned with read data. WRITE Data Strobe: Input with write data. WDQS is center-aligned to the input data. No Connect: No internal electrical connection is present.
CKE
Input
CS RAS, CAS, WE DM0 ~DM3 BA0, BA1
Input Input Input
Input
A0 ~ A11
Input
DQ0 ~ DQ31 RDQS0 ~ RDQS3 WDQS0 ~ WDQS3 NC/RFU VDDQ VSSQ VDD VSS VREF ZQ RES
Input/ Output Output Input
Supply Supply Supply Supply Supply
DQ Power Supply: 2.0V 0.1V DQ Ground Power Supply: 2.0V 0.1V Ground Reference voltage: 0.7*VDDQ , 2 Pins : (M,2) for Data input , (M,13) for CMD and ADDRESS
Reference Resistor connection pin for On-die termination. The value of Resistor = 240 Input Reset pin: RESET pin is a VDDQ CMOS input
-6-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
BLOCK DIAGRAM (2Mbit x 32I/O x 4 Bank)
WDQS
256M GDDR3 SDRAM
Input Buffer
32
Input Buffer I/O Control LWE LDMi
Bank Select
Data Input Register Serial to parallel
128
2M x 32 Output Buffer 4-bit prefetch Sense AMP Refresh Counter Row Buffer Row Decoder 2M x 32 2M x 32 2M x 32
128 32
x32
DQi
Address Register
iCK ADDR
Column Decoder LCBR LRAS Col. Buffer
Latency & Burst Length Strobe Gen. RDQS
Programming Register LCKE LRAS LCBR LWE LCAS LWCBR
Output DLL
CK,CK
LDMi
Timing Register
iCK
CKE
CS
RAS
CAS
WE
DMi
* iCK : internal clock
-7-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
FUNCTIONAL DESCRIPTION
Simplified State Diagram
Power Applied Power On
256M GDDR3 SDRAM
Precharge PREALL
Self Refresh REFS REFSX
MRS EMRS
MRS
Idle
REFA
Auto Refresh
CKEL CKEH
Active Power Down CKEH CKEL
ACT
Precharge Power Down
Row Active Write Write A Write Write Read A Read
Read
Read
Write A Read A Write A PRE PRE PRE
Read A
Read A
PRE
Precharge PREALL Automatic Sequence Command Sequence
PREALL = Precharge All Banks MRS = Mode Register Set EMRS = Extended Mode Register Set REFS = Enter Self Refresh REFSX = Exit Self Refresh REFA = Auto Refresh
CKEL = Enter Power Down CKEH = Exit Power Down ACT = Active Write A = Write with Autoprecharge Read A = Read with Autoprecharge PRE = Precharge
-8-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
INITIALIZATION
256M GDDR3 SDRAM
GDDR3 SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation.
1. Apply power and keep CKE/RESET at low state ( All other inputs may be undefined) - Apply VDD and VDDQ simultaneously - Apply VDDQ before Vref. ( Inputs are not recognized as valid until after VREF is applied ) 2. Required minimum 100us for the stable power before RESET pin transition to HIGH - Upon power-up the address/command active termination value will automatically be set based off the state of RESET and CKE. - On the rising edge of RESET the CKE pin is latched to determine the address and command bus termination value. If CKE is sampled at a zero the address termination is set to 1/2 of ZQ. If CKE is sampled at a one the address termination is set to ZQ. - RESET must be maintained at a logic LOW level and CS at a logic high value during power-up to ensure that the DQ outputs will be in a High-Z state, all active terminators off, and all DLLs off. 4. Minimum 200us delay required prior to applying any executable command after stable power and clock. 5. Once the 200us delay has been satisfied, a DESELECT or NOP command should be applied, then RESET and CKE should be brought to HIGH, 6. Issue a PRECHARGE ALL command following after NOP command. 7. Issue a dummy MRS command ("00001000100001") 8. Issue a EMRS command (BA1BA0="01") to enable the DLL. 9. Issue MRS command (BA0BA1 = "00") to reset the DLL and to program the operating parameters. 20K clock cycles are required to lock the DLL. 9. Issue a PRECHARGE ALL command 10 . Issue at least two AUTO refresh command to update the driver impedance and calibrate the output drivers. Following these requirements, the GDDR3 SDRAM is ready for normal operation.
VDDQ
VDD
VREF
T0
CK CK
T1
Ta0
Tb0
Tc0
Td0
Te0
Tf0
RES
tATS t
t
CH
tCL
ATH
t
IS
t
IH
CKE CKE
tIS t
IH
COMMAND
NOP
PRE
Dummy MRS
EMRS
MRS
PRE
AR
AR
ACT
DM
t
IS
tIH
t
IS
tIH
CODE A0-A7, A9-A11 A8
t
CODE
t
CODE
RA
ALL BANKS
t
IS
t
IH
IS
t
IH
ALL BANKS
CODE
t
CODE
IS
t
CODE
t
RA
IS
t
IH
t
IS
tIH
IS
tIH
IH
BA0, BA1 RDQS WDQS DQ T = 200us T=10ns Power-up: VDD and CK stable tRP Precharge All Banks High High High
BAO=L, BA1 =L
BAO=H, BA1 =L
BAO=L, BA1 =L
BA
tMRD Load Mode Register (Dummy MRS) Load Extended Mode Register
tMRD
tMRD
tRP 1st Auto Refresh
tRFC 2nd Auto Refresh
tRFC
20K cycle Load Mode Register Precharge DLL Reset All Banks
-9-
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
MODE REGISTER SET(MRS)
256M GDDR3 SDRAM
The mode register stores the data for controlling the various operating modes of GDDR3 SDRAM. It programs CAS latency, addressing mode, test mode and various vendor specific options to make GDDR3 SDRAM useful for variety of different applications. The default value of the mode register is not defined, therefore the mode register must be written after EMRS setting for proper operation. The mode register is written by asserting low on CS, RAS, CAS and WE (The GDDR3 SDRAM should be in active mode with CKE already high prior to writing into the mode register). The state of address pins A0 ~ A11 and BA0, BA1 in the same cycle as CS, RAS, CAS and WE going low is written in the mode register. Minimum six clock cycles are requested to complete the write operation in the mode register. The mode register contents can be changed using the same command and clock cycle requirements during operation as long as all banks are in the idle state. The mode register is divided into various fields depending on functionality. The Burst length uses A0 ~ A2. CAS latency (read latency from column address) uses A4 ~ A6. A7 is used for test mode. A8 is used for DLL reset. A9 ~ A11 are used for Write latency. Refer to the table for specific codes for various addressing modes and CAS latencies.
BA1
BA0
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
0
0
WL
DLL
TM
CAS Latency
BT
Burst Length
Test Mode BA0 0 1 An ~ A0 MRS EMRS A7 0 1 mode Normal Test
Burst Type A3 0 1 Burst Type Sequential Reserved
DLL Write Latency A11 0 0 0 0 1 1 1 1 A10 0 0 1 1 0 0 1 1 A9 0 1 0 1 0 1 0 1 Write Latency Reserved 1 2 3 4 5 6 Reserved CAS Latency A6 0 0 0 0 1 1 1 1 A5 0 0 1 1 0 0 1 1 A4 0 1 0 1 0 1 0 1 CAS Latency 8 9 Reserved Reserved Reserved 5 6 7 A8 0 1 DLL Reset No Yes Burst Length A2 0 0 0 0 1 1 1 1 A1 0 0 1 1 0 0 1 1 A0 0 1 0 1 0 1 0 1 Burst Length Reserved Reserved 4 Reserved Reserved Reserved Reserved Reserved
- 10 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
256M GDDR3 SDRAM
PROGRAMMABLE IMPEDANCE OUTPUT BUFFER AND ACTIVE TERMINATOR
The GDDR3 SDRAM is equipped with programmable impedance output buffers and Active Terminators. This allows a user to match the driver impedance to the system. To adjust the impedance, an external precision resistor(RQ) is connected between the ZQ pin and Vss. The value of the resistor must be six times the desired output impedance. For example, a 240 resistor is required for an output impedance of 40. To ensure that output impedance is one sixth the value of RQ (within 10 %), the range of RQ is 120 to 360 (20 to 60 output impedance). RES, CK and /CK are not internally terminated. CK and /CK will be terminated on the system module using external 1% resisters. The output impedance is updated during all AUTO REFRESH commands and NOP commands when a READ is not in progress to compensate for variations in supply voltage and temperature. The output impedance updates are transparent to the system. Impedance updates do not affect device operation, and all data sheet timing and current specifications are met during an update. To guarantee optimum output driver impedance after power-up, the GDDR3(x32) needs 20us after the clock is applied and stable to calibrate the impedance upon power-up. The user can operate the part with fewer than 20us, but optimal output impedance is not guaranteed. The value of ZQ is also used to calibrated the internal address/command termination resisters. The two termination values that are selectable at power up are 1/ 2 of ZQ and ZQ. The value of ZQ is used to calibrate the internal DQ termination resisters. The two termination values that are selectable are 1/4 of ZQ and 1/2 of ZQ.
BURST LENGTH
Read and write accesses to the GDDR3 SDRAM are burst oriented, with the burst length being programmable, as shown in MRS table. The burst length determines the maximum number of column locations that can be accessed for a given READ or WRITE command. Burst length of 4 only is available. Reserved states should not be used, as unknown operation or incompatibility with future versions may result. When a READ or WRITE command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within the block, meaning that the burst will wrap within the block if a boundary is reached. The block is uniquely selected by A2-Ai when the burst length is set to four (Where Ai is the most significant column address bit for a given configuration). The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. The programmable burst length applies to both READ and WRITE bursts.
BURST TYPE
Accesses within a given burst must be programmed to be sequential; this is referred to as the burst type and is selected via bit A3. This device does not support the interleaved burst mode found in DDR SDRAM devices. The ordering of accesses within a burst is determined by the burst length, the burst type, and the starting column address, as shown in below table: Burst Definition
Burst Definition Burst Length 4 Starting Column Address A1 0 A0 0 0-1-2-3 Order of Access within A burst Type= Sequential
NOTE : 1. For a burst length of four, A2-A7 select the block of four burst; A0-A1 select the starting column within the block and must be set to zero
- 11 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
CAS LATENCY (READ LATENCY)
256M GDDR3 SDRAM
The CAS latency is the delay, in clock cycles, between the registration of a READ command and the availability of the first bit of output data. The latency can be set to 5~9 clocks. If a READ command is registered at clock edge n, and the latency is m clocks, the data will be available nominally coincident with clock edge n+m. Below table indicates the operating frequencies at which each CAS latency setting can be used. Reserved states should not be used as unknown operation or incompatibility with future versions may result.
CAS Latency Allowable operating Frequency (MHz) SPEED -12 -14 -16 -20 CL=9
800 700
CL=8 600
CL=7 500
CL=6 -
CL=5 -
-
-
T0
T3
T4
T5
T5n

/CK CK
COMMAND
READ
NOP CL = 5
NOP
NOP
RDQS
DQ
T0
T4
T5
T6
T6n

/CK CK
COMMAND
READ
NOP CL = 6
NOP
NOP
RDQS
DQ
Burst Length = 4 in the cases shown Shown with nominal tAC and nominal tDSDQ DON'T CARE TRANSITIONING DATA
- 12 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
WRITE LATENCY
256M GDDR3 SDRAM
The Write latency (WL) is the delay, in clock cycles, between the registration of a WRITE command and the availability of the first bit of input data. The latency can be set from 1 to 6 clocks depending in the operating frequency and desired current draw. When the write latencies are set to 1 or 2 or 3 clocks, the input receivers never turn off when the WRITE command is registered. If a WRITE command is registered at clock edge n, and the latency is m clocks, the data will be available nominally coincident with clock edge n+m. Reserved states should not be used as unknown operation or incompatibility with future versions may result.
* Maximum frequency of GDDR3 can be limited in WL4, 5 and 6
T0 /CK CK
T1
T2
T3
T3n
COMMAND
WRITE
NOP WL = 3
NOP
NOP
WDQS
DQ
T0
T2
T3
T4
T4n

/CK CK
COMMAND
WRITE
NOP WL = 4
NOP
NOP
WDQS
DQ
Burst Length = 4 in the cases shown
DON'T CARE
TRANSITIONING DATA
- 13 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
TEST MODE
256M GDDR3 SDRAM
The normal operating mode is selected by issuing a MODE REGISTER SET command with bits A7 set to zero, and bits A0-A6 and A8A11 set to the desired values. Test mode is entered by issuing a MODE REGISTER SET command with bit A7 set to one, and bits A0A6 and A8-A11 set to the desired values. Test mode functions are specific to each Dram Manufacturer and its exact functions are hidden from the user.
DLL RESET
The normal operating mode is selected by issuing a MODE REGISTER SET command with bit A8 set to zero, and bits A0-A7 and A9A11 set to the desired values. A DLL reset is initiated by issuing a MODE REGISTER SET command with bit A8 set to one, and bits A0A7 and A9-A11 set to the desired values. When a DLL Reset is complete the GDDR3 SDRAM reset bit 8 of the mode register to a zero. After DLL Reset MRS, Power down can not be issued during 10 clock.
- 14 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
EXTENDED MODE REGISTER SET(EMRS)
256M GDDR3 SDRAM
The extended mode register stores the data output driver strength and on-die termination options. The extended mode register is written by asserting low on CS, RAS, CAS, WE and high on BA0(The GDDR3 SDRAM should be in all bank precharge with CKE already high prior to writing into the extended mode register). The state of address pins A0 ~ A11 and BA0 in the same cycle as CS, RAS, CAS and WE going low are written in the extended mode register. Six clock cycles are required to complete the write operation in the extended mode register. 4 kinds of the output driver strength are supported by EMRS (A1, A0) code. The mode register contents can be changed using the same command and clock cycle requirements during operation as long as all banks are in the idle state. "High" on BA0 is used for EMRS. Refer to the table for specific codes.
BA1
BA0
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
0
1
LP
ID
AL
tWR
DLL
tWR
Termination
Drive Strength
Vendor ID BA0 0 1 An ~ A0 MRS EMRS A10 0 1 Vendor ID Off On
DLL A6 0 1 DLL Enable Disable
Drive Strength A1 0 0 1 1 A0 0 1 0 1 Drive Strength Autocal 30 40 50
Additive Latency A9 0 0 1 1 A8 0 1 0 1 AL 0 1 Reserved Reserved tWR A7 0 0 0 0 Low Power A11 0 1 Low Power Disable Enable 1 1 1 1 A5 0 0 1 1 0 0 1 1 A4 0 1 0 1 0 1 0 1 tWR 3 4 5 6 7 Reserved Reserved Reserved Termination A3 0 0 1 1 A2 0 1 0 1 Termination ODT Disabled Reserved ZQ/4 ZQ/2
* ZQ : Resistor connection pin for On-die termination
- 15 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
DLL ENABLE/DISABLE
256M GDDR3 SDRAM
The DLL must be enabled for normal operation. DLL enable is required during power-up initialization and upon returning to normal operation after disabling the DLL for debugging or evaluation. (When the device exits self refresh mode, the DLL is enabled automatically.) Any time the DLL is enabled, 20K clock cycles must occur before a READ command can be issued.
DATA TERMINATION
The Data Termination, DT, is used to determine the value of the internal data termination resisters. The GDDR3 SDRAM supports 60 and 120 termination. The termination may also be disabled for testing and other purposes.
DATA DRIVER IMPEDANCE
The Data Driver impedance (DZ) is used to determine the value of the data drivers impedance. When autocalibration is used the data driver impedance is set to 40s and it's tolerance is determined by the calibration accuracy of the device. When any other value is selected the target impedance is set nominally to the desired impedance. However, the accuracy is now determined by the device's specific process corner, applied voltage and operating temperature.
ADDITIVE LATENCY
The Additive Latency function (AL) is used to optimize the command bus efficiency. The AL value is used to determine the number of clock cycles that is to be added to CL after CAS is captured by the rising edge of CK. Thus the total CAS latency is determined by adding CL and AL.
MANUFACTURERS VENDOR CODE AND REVISION IDENTIFICATION
The Manufacturers Vendor Code, V, is selected by issuing a EXTENDED MODE REGISTER SET command with bits A10 set to one, and bits A0-A9 and A11 set to the desired values. When the V function is enabled the GDDR3 SDRAM will provide its manufacturers vendor code on DQ[3:0] and revision identification on DQ[7:4]
Manufacturer Reserved Samsung Infineon Elpida Etron Nanya
DQ[3:0] 0 1 2 3 4 5
Manufacturer Hynix Mosel Winbond ESMT Reserved Reserved
DQ[3:0] 6 7 8 9 A B
Manufacturer Reserved Reserved Reserved Micron
DQ[3:0] C D E F
- 16 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
LOW POWER MODE
256M GDDR3 SDRAM
Low power mode can be enabled by A11="H" during the EMRS command and in this case, Precharge Power Down command activates LP mode1 and Self Refresh command activates LP mode2. In case that A11 set to "L" during the EMRS, Low Power mode is disabled and Precharge Power Down command and Self Refresh command will do normal operation. If a Precharge Power Down command issued under the condition of Low Power mode enabled, a device enters the LP mode1 and it can reduce Precharge Power Down current significantly by disabling DLL during the Precharge Power Down, however it requires more time to exit Power Down. If the power down duration is less than 20us, the required tPDEX is 300tCK. Otherwise, 20000tCK required for the tPDEX. If a Self Refresh command issued under the condition of Low Power mode enabled, a device enters the LP mode2 and it can reduce tXSR while slightly increase the Self Refresh current. If the Self Refresh duration is less than 20us, the required tXSR is 300tCK. Otherwise, 20000tCK required for the tXSR.
Low Power Command
Disabled (A11="L" @ EMRS)
Enabled (A11="H" @ EMRS)
Comments . DLL disabled for the purpose of current saving ( ICC2P minimized) . tPDEX increased - 300tCK@ power down exit within 20us - 20KtCK@ power down exit after 20us . Short tXSR - 300tCK@ Self Refresh exit within 20us - 20KtCK@ Self Refresh exit after 20us
Precharge Power Down
Precharge Power Down
LP Mode1
Self Refresh
Self Refresh
LP Mode2
- 17 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
COMMANDS
256M GDDR3 SDRAM
Below Truth table-COMMANDs provides a quick reference of available commands. This is followed by a verbal description of each command. Two additional Truth Tables appear following the operation section : these tables provide current state/next state information.
TRUTH TABLE - COMMANDs
Name (Function) DESELECT (NOP) NO OPERATION (NOP) ACTIVE (Select bank and activate row) READ (Select bank and column, and start READ burst) WRITE (Select bank and column, and start WRITE burst) PRECHARGE (Deactivate row in bank or banks) AUTO REFRESH or SELF REFRESH (Enter self refresh mode) LOAD MODE REGISTER DATA TERMINATOR DISABLE CS H L L L L L L L X RAS X H L H H L L L H CAS X H H L L H L L L WE X H H H L L H L H ADDR X X Bank/Row Bank/Col Bank/Col Code X Op-Code X NOTES 8, 11 8 3 4 4 5 6, 7 2
TRUTH TABLE - DM Operation
Name (Function) Write Enable Write Inhibit DM L H DQS Valid X 10 NOTES
Note :
1. CKE is HIGH for all commands except SELF REFRESH. 2. BA0~BA1 select either the mode register or the extended mode register (BA0=0, BA1=0 select the mode register; BA0=1, BA1=0 select extended mode register; other combinations of BA0~BA1 are reserved). A0~A11 provide the op-code to be written to the selected mode register. 3. BA0~BA1 provide bank address and A0~A11 provide row address. 4. BA0~BA1 provide bank address; A0~A7 and A9 provide column address; A8 HIGH enables the auto precharge feature (nonpersistent) , and A8 LOW disables the auto precharge feature. 5. A8 LOW : BA0~BA1 determine which bank is precharged. A8 HIGH : All banks are precharged and BA0~BA1 are "Don't Care." 6. This command is AUTO REFRESH if CKE is HIGH, SELF REFRESH if CKE is LOW. 7. Internal refresh counter controls row addressing; ll inputs and I/Os are "Don't Care" except for CKE. 8. DESELECT and NOP are functionally interchangeable. 9. Cannot be in powerdown or self-refresh state. 10. Used to mask write data ; provided coincident with the corresponding data. 11. Except DATA Termination disable.
- 18 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
DESELECT
256M GDDR3 SDRAM
The DESELECT function (/CS high) prevents new commands from being executed by the DDR(x32). The GDDR3(x32) SDRAM is effectively deselected. Operations already in progress are not affected.
NO OPERATION (NOP)
The NO OPERATION (NOP) command is used to instruct selected GDDR3(x32) to perform a NOP (/CS LOW). This prevents unwanted commands from being registered during idle or wait states. Operations already in progress are not affected.
LOAD MODE REGISTER
The mode registers are loaded via inputs A0-A11. See mode register descriptions in the Register Definition section. The Load Mode Register command can only be issued when all banks are idle, and a subsequent executable command cannot be issued until tMRD is met.
ACTIVE
The ACTIVE command is used to open (or activate) a row in a particular bank for a subsequent access. The value on the BA0,BA1 inputs selects the bank, and the address provided on inputsA0-A11 selects the row. This row remains active (or open) for accesses until a PRECHARGE command is issued to that bank. A PRECHARGE command must be issued before opening a different row in the same bank.
READ
The READ command is used to initiate a burst read access to an active row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A7, A9 selects the starting column location. The value on input A8 determines whether or not auto precharge is used. If auto precharge is selected, the row being accessed will be precharged at the end of the READ burst; if auto precharge is not selected, the row will remain open for subsequent accesses.
WRITE
The WRITE command is used to initiate a burst write access to an active row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A7, A9 selects the starting column location. The value on inputs A8 determines whether or not auto precharge is used. If auto precharge is selected, the row being accessed will be precharged at the end of the WRITE burst; if auto precharge is not selected, the row will remain open for subsequent accesses. Input data appearing on the DQs is written to the memory array subject to the DM input logic level appearing coincident with the data. If a given DM signal is registered LOW. the corresponding data will be written to memory; If the DM signal is registered HIGH, the corresponding data inputs will be ignored, and a WRITE will not be executed to that byte/column location.
PRECHARGE
The PRECHARGE command is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) will be available for a subsequent row access a specified time (tRP) after the PRECHARGE command is issued. Input A8 determines whether one or all banks are to be precharged, and in the case where only one banks are to be precharged, inputs BA0,BA1 select the bank. Otherwise BA0, BA1 are treated as "Don't Care." Once a bank has been precharged, it is in the idle state and must be activated prior to any READ or WRITE command will be treated as a NOP if there is no open row is already in the process of precharging.
- 19 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
AUTO PRECHARGE
256M GDDR3 SDRAM
Auto precharge is a feature which performs the same individual-bank precharge function described above, but without requiring an explicit command. This is accomplished by using A8 to enable auto precharge in conjunction with a specific READ or WRITE command. A precharge of the bank/row that is addressed with the READ or WRITE command is automatically performed upon completion of the READ or WRITE burst. Auto precharge is nonpersistent in that it is either enable or disabled for each individual READ or WRITE command. Auto precharge ensures that the precharge is initiated at the earliest valid state within a burst. This "earliest valid stage" is determined as if an explicit PRECHARGE command was issued at the earliest possible time, without violating tRAS(min), as described for each burst type in the Operation section of this data sheet. The user must not issue another command to the same bank until the precharge time(tRP) is completed.
AUTO REFRESH
Auto Refresh is used during normal operation of the GDDR3 SDRAM and is analogous to /CAS-BEFORE-/RAS (CBR) REFRESH in FPM/EDO DRAMs. This command is nonpersistent, so it must be issued each time a refresh is required. The addressing is generated by the internal refresh controller. This makes the address bits a "Don't Care" during an Auto Refresh command. The 256Mb(x32) DDR2(x32) requires Auto Refresh cycles at an average interval of 7.8us (maximum). A maximum of eight Auto Refresh commands can be posted to any given GDDR3(x32) SDRAM, meaning that the maximum absolute interval between any Auto Refresh command and the next Auto Refresh command is 9 x 7.8us(70.2us). This maximum absolute interval is to allow GDDR3(x32) SDRAM output drivers and internal terminators to automatically recalibrate compensating for voltage and temperature changes.
SELF REFRESH
The SELF REFRESH command can be used to retain data in the GDDR3(x32) SDRAM ,even if the rest of the system is powered down. When in the self refresh mode,the GDDR3(x32) SDRAM retains data without external clocking. The SELF REFRESH command is initiated like an AUTO REFRESH command except CKE is disabled (LOW). The DLL is automatically disabled upon entering SELF REFRESH and is automatically enabled and reset upon exiting SELF REFRESH. The active termination is also disabled upon entering Self Refresh and enabled upon exiting Self Refresh. (200 clock cycles must then occur before a READ command can be issued). Input signals except CKE are "Don't Care" during SELF REFRESH. The procedure for exiting self refresh requires a sequence of commands. First, CK and /CK must be stable prior to CKE going back HIGH. Once CKE is HIGH,the GDDR3(x32) must have NOP commands issued for tXSNR because tine is required for the completion of any internal refresh in progress. A simple algorithm for meeting both refresh, DLL requirements and out-put calibration is to apply NOPs for 200 clock cycles before applying any other command to allow the DLL to lock and the output drivers to recalibrate.
DATA TERMINATOR DISABLE (BUS SNOOPING FOR READ COMMAND)
The DATA TERMINATOR DISABLE COMMAND is detected by the device by snooping the bus for READ commands excluding /CS. The GDDR3 DRAM will disable its Data terminators when a READ command is detected. The terminators are disable CL-1 Clocks after the READ command is detected. In a two rank system both dram devices will snoop the bus for READ commands to either device and both will disable their terminators if a READ command is detected. The command and address terminators and always enabled.
- 20 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
ON-DIE TERMINATION
256M GDDR3 SDRAM
Bus snooping for READ commands other than /CS is used to control the on-die termination. The GDDR3 SDRAM will disable the on-die termination when a READ command is detected, regardless of the state of /CS. The on-die termination is disabled x clocks after the READ command where x equals CL-1 and stay off for a duration of BL/2 + 2, as below figure, Data Termination Disable Timing. In a two-rank system, both DRAM devices snoop the bus for READ commands to either device and both will disable the on-die termination if a READ command is detected. The on-die termination for all other pins on the device are always on for both a single-rank system and a dual-rank system. The on-die termination value on address and control pins is determined during power-up in relation to the state of CKE on the first transition of RESET. On the rising edge of RESET, if CKE is sampled LOW, then the configuration is determined to be a single-rank system. The on-die termination is then set to one-half ZQ for the address pins. On the rising edge of RESET, if CKE is sampled HIGH, then the configuration is determined to be a dual-rank system. The on-die termination for the DQs, WDQS, and DM pins is set in the EMRS.
Data Termination Disable Timing
T0 CK# CK T7 T8 T8n T9 T9n T10 T11

COMMAND
READ
NOP
NOP
NOP
NOP
NOP
ADDRESS
Bank a, Col n CL = 8

RDQS
DO n
DQ
DQ TERMINATION
GDDR3 Data Termination is Disabled
DON'T CARE Note : 1. DO n = data-out from column n. 2. Burst length = 4. 3. Three subsequent elements of data-out appear in the specified order following DO n. 4. Shown with nominal tAC and tDQSQ. 5. RDQS will start driving high one-half cycle prior to the first falling edge. 6. The Data Terminators are disabled starting at CL-1 and the duration is BL/2 + 2 7. READS to either rank disable both ranks' termination regardless of the logic level of /CS.
TRANSITIONING DATA
- 21 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC OPERATIONS
BANK/ROW ACTIVATION
256M GDDR3 SDRAM
/CK CK CKE /CS HIGH
Before any READ or WRITE commands can be issued to a banks within the GDDR3 SDRAM, a row in that bank must be "opened." This is accomplished via the ACTIVE command, which selects both the bank and the row to be activated. After a row is opened with an ACTIVE command, a READ or WRITE command may be issued to that row, subject to the tRCD specification. tRCD(min) should be divided by the clock period and rounded up to the next whole number to determine the earliest clock edge after the ACTIVE command in which a READ or WRITE command can be entered. For example, a tRCD specification of 16ns with a 450MHz clock (2.2ns period) results in 7.2 clocks rounded to 8. This is reflected in below figure, which covers any case where 7/RAS
/CAS
/WE
A0-A11
RA
BA0,1
BA RA = Row Address BA = Bank Address
Activating a Specific Row in a Specific Bank
Example : Meeting tRCD
T0 /CK CK T1 T2 T3 T4 T7 T8 T9
COMMAND ACT NOP NOP ACT NOP
NOP RD/WR NOP
A0-A11
Row
Row
Col

BA0, BA1
Bank x tRRD

Bank y
Bank y
tRCD DON'T CARE
- 22 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
READs
READ bursts are initiated with a READ command, as below figure. The starting column and bank addresses are provided with the READ command and auto precharge is either enabled or disabled for that burst access. If auto precharge is enabled, the row being accessed is prechrged at the completion of the burst after tRAS(min) has been met. For the generic READ commands used in the following illustrations, auto precharge is disabled. During READ bursts, the valid data-out element from the starting column address will be available following the CAS Latency after the READ command. Each subsequent data-out element will be valid nominally at the next positive or negative strobe edge. READ burst figure shows general timing for 2 of the possible CAS latency settings. The GDDR3(x32) drives the output data edge aligned to the crossing of CK and /CK and to RDQS. The initial HIGH transitioning LOW of RDQS is known as the read preamble ; the half cycle coincident with the last data-out element is known as the read postamble. Upon completion of a burst, assuming no other commands have been initiated, the DQs will go High-Z. A detailed explanation of tDQSQ (valid data-out skew), tDV (data-out window hold), the valid data window are depicted in Data Output Timing (1) figure. A detailed explanation of tAC (DQS and DQ transition skew to CK) is shown in Data Output Timing (2) figure. Data from any READ burst may be concatenated with data from a subsequent READ command. A continuous flow of data can be maintained. The first data element from the new burst follows the last element of a completed burst. The new READ command should be issued x cycles after the first READ command, where x equals the number of data element nibbles (nibbles are required by the 4n-prefetch architecture) depending on the burst length. This is shown in consecutive READ bursts figure. Nonconsecutive read data is shown for illustration in nonconsecutive READ bursts figure. Full-speed random read accesses within a page (or pages) can be performed as shown in Random READ accesses figure. Data from a READ burst cannot be terminated or truncated. During READ commands the GDDR3 Dram disables its data terminators.
256M GDDR3 SDRAM
/CK CK CKE /CS HIGH
/RAS
/CAS
/WE
A0-A7, A9
CA
A10, A11 EN AP A8 DIS AP BA0,1 BA
CA = Column Address BA = Bank Address EN AP = Enable Auto Precharge DIS AP = Disable Auto Precharge DON'T CARE
READ Command
- 23 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Data Output Timing (1) - tDQSQ, tQH and Data Valid Window
T0 CK# CK tCH tCL tDQSQ2 (MAX) RDQS
1.6
256M GDDR3 SDRAM
T1
T2
T2n
T3
T3n
T4
tDQSQ2 (MAX) tDQSQ2 (MIN)
tDQSQ (MIN)
2
DQ(Last data valid)
tDQSH4
T2
tDQSH4
T2n T3 T3n
DQ(First data no longer valid)
T2
T2n
T3
T3n
All DQs and RDQS, collectively5
T2
T2n
T3
T3n
tDV4
tDV4
tDV4
tDV4
Data Output Timing (2) - tDQSQ, tQH and Data Valid Window
T0 CK# CK tCH tAC(MAX) RDQS 1.6 All DQs and RDQS, collectively5
T2
T1
T2
T2n
T3
T3n
T4
tCL
tDQSH4
T2n
tDQSH4
T3 T3n
RDQS 1.6 All DQs and RDQS, collectively5
tAC(MIN)
tDQSH4
T2 T2n
tDQSH4
T3 T3n
Note : 1. tDQSQ represents the skew between the 8 DQ lines and the respective RDQS pin. 2. tDQSQ is derived at each RDQS clock edge and is not cumulative over time and begins with first DQ transition and ends with the last valid transition of DQs. 3. tAC is show in the nominal case 4. tDQHP is the lesser of tDQSL or tDQSH strobe transition collectively when a bank is active. 5. The data valid window is derived for each RDQS transitions and is defined by tDV. 6. There are 4 RDQS pins for this device with RDQS0 in relation to DQ0-DQ7, RDQS1 in relation DQ8-DQ15, RDQS2 in relation to DQ16-24 and RDQS3 in relation to DQ25-DQ31. 7. This diagram only represents one of the four byte lanes. 8. tAC represents the relationship between DQ, RDQS to the crossing of CK and /CK.
- 24 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
READ Burst
T0

256M GDDR3 SDRAM
T7
T8
T8n
T9
T9n
T10
T11
/CK CK

COMMAND
READ
NOP
NOP
NOP
NOP
NOP

ADDRESS
Bank a, Col n CL = 8
RDQS
DQ
DO n
T0

T7
T8
T9
T9n
T10
T11
/CK CK COMMAND READ ADDRESS Bank a, Col n CL = 9 RDQS

NOP
NOP
NOP
NOP
NOP
DQ
DO n
DON'T CARE
NOTE :
TRANSITIONING DATA
1. DO n=data-out from column n. 2. Burst length = 4 3. Three subsequent elements of data-out appear in the programmed order following DQ n. 4. Shown with nominal tAC and tDQSQ. 5. RDQS will start driving high 1/2 clock cycle prior to the first falling edge.
- 25 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Consecutive READ Bursts
T0 /CK CK T1 T2 T8 T8n
256M GDDR3 SDRAM
T9
T9n
T10
T10n

COMMAND
READ
NOP
READ
NOP
NOP
NOP

ADDRESS
Bank a, Col n CL = 8
Bank a, Col b
RDQS

DQ
DO n
DO b
DON'T CARE
TRANSITIONING DATA
NOTE : 1. DO n (or b) = data-out from column n (or column b). 2. Burst length = 4 3. Three subsequent elements of data-out appear in the programmed order following DQ n. 4. Three subsequent elements of data-out appear in the programmed order following DQ b. 5. Shown with nominal tAC and tDQSQ. 6. Example applies when READ commands are issued to different devices or nonconsecutive READs. 7. RDQS will start driving high one half-clock cycle prior to the first falling edge of RDQS.
- 26 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Nonconsecutive READ Bursts
T0

256M GDDR3 SDRAM
T7
T8
T8n
T9
T9n
T10
T17
T17n
T18
/CK CK

COMMAND
READ
NOP
NOP
READ
NOP
NOP
NOP


ADDRESS
Bank a, Col n CL = 8
Bank a, Col b

RDQS


DQ
DO n
DO b
DON'T CARE
TRANSITIONING DATA
NOTE : 1. DO n (or b) = data-out from column n (or column b). 2. Burst length = 4 3. Three subsequent elements of data-out appear in the programmed order following DQ n. 4. Three subpsequent elements of data-out appear in the programmed order following DQ b. 5. Shown with nominal tAC and tDQSQ. 6. Example applies when READ commands are issued to different devices or nonconsecutive READs. 7. RDQS will start driving high one half-clock cycle prior to the first falling edge of RDQS.
- 27 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Random READ Accesses
T0 /CK CK T1 T2

256M GDDR3 SDRAM
T8
T8n
T9
T9n
T10
T10n
COMMAND
READ
NOP
READ
NOP
NOP
NOP

ADDRESS
Bank a, Col n CL = 8
Bank a, Col b
RDQS

DQ
DO n
DO n
DO n
DO n
DO b
T0 /CK CK
T1

T7
T8
T8n
T9
T9n
T10
T10n
COMMAND
READ
NOP
READ
NOP
NOP
NOP

ADDRESS
Bank a, Col n CL = 8
Bank a, Col b
RDQS

DQ
DO n
DO n
DO n
DO n
DON'T CARE NOTE :
TRANSITIONING DATA
1. DO n (or x or b or g) = data-out from column n (or column x or column x or column b or column g). 2. Burst length = 4 3. n' or x or b' or g' indicates the next data-out following DO n or DO x or DO b OR DO g, respectively 4. READs are to an active row in any bank. 5. Shown with nominal tAC and tDQSQ. 6. RDQS will start driving high one half-clock cycle prior to the first falling edge of RDQS.
- 28 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
READ to WRITE
T0 T7 T8 T8n T9 T9n T10
256M GDDR3 SDRAM
T11
T12
T12n

/CK CK COMMAND
READ
NOP
WRITE
NOP
NOP
NOP
NOP
ADDRESS
Bank Col n
Bank a, Col b CL = 8
RDQS
tWL = 4

WDQS
DQ
DO n
DI b

DM

DQ Termination
DQ Termination Disabled
DQ Termination Enbaled 1tCK <
DON'T CARE NOTE :
TRANSITIONING DATA
1. DO n = data-out from column n. 2. DI b = data-in from column b. 3. Burst length = 4 4. One subsequent element of data-out appears in the programmed order following DO n. 5. Data-in elements are applied following DI b in the programmed order. 6. Shown with nominal tAC and tDQSQ. 7. tDQSS in nominal case. 8. RDQS will start driving high one half-clock cycle prior to the first falling edge of RDQS. 9. The gap between data termination enable to the first data-in should be greater than 1tCK
- 29 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
READ to PRECHARGE
T0 /CK CK T1 T2

256M GDDR3 SDRAM
T8
T8n
T9
T9n
T10
COMMAND
READ
NOP
PRE
NOP
NOP
ACT
ADDRESS
Bank a, Col n CL = 8
Bank a
Bank a, Row

tRP
RDQS

DQ
DO n
DON'T CARE
TRANSITIONING DATA
NOTE : 1. DO n (or b) = data-out from column n (or column b). 2. Burst length = 4 3. Three subsequent elements of data-out appear in the programmed order following DQ n. 4. Read to precharge equals two clocks, which enables two data pairs of data-out. 5. Shown with nominal tAC and tDQSQ. 6. Example applies when READ commands are issued to different devices or nonconsecutive READs. 7. RDQS will start driving high one half-clock cycle prior to the first falling edge of RDQS.
- 30 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
WRITEs
WRITE bursts are initiated with a WRITE command, as shown in Figure. The starting column and bank addresses are provided with the WRITE command, and auto precharge is either enabled or disabled for that access. If auto precharge is enabled, the row being accessed is precharged at the completion of the burst. For the generic WRITE commands used in the following illustrations, auto precharge is disabled. During WRITE bursts, the first valid data-in element will be registered in a rising edge of WDQS following the WRITE latency set in the mode register and subsequent data elements will be registered on successive edges of WDQS. Prior to the first valid WDQS edge a half cycle is needed and specified as the WRITE Preamble; the half cycle in WDQS following the last data-in element is known as the write postamble. The time between the WRITE command and the first valid falling edge of WDQS (tDQSS) is specified with a relative to the write latency. All of the WRITE diagrams show the nominal case, and where the two extreme cases (i.e., tDQSS(min) and tDQSS(max)) might not be intuitive, they have also been included. Write Burst figure shows the nominal case and the extremes of tDQSS for a burst of 4. Upon completion of a burst, assuming no other commands have been initiated, the DQs will remain High-Z and any additional input data will be ignored. Data for any WRITE burst may not be truncated with a subsequent WRITE command. The new WRITE command can be issued on any positive edge of clock following the previous WRITE command after the burst has completed. The new WRITE command should be issued x cycles after the first WRITE command should be equals the number of desired nibbles (nibbles are required by 4n-prefetch architecture). An example of nonconsecutive WRITEs is shown in Nonconsecutive WRITE to READ figure. Full-speed random write accesses within a page or pages can be performed as shown in Random WRITE cycles figure. Data for any WRITE burst may be followed by a subsequent READ command. Data for any WRITE burst may be followed by a subsequent PRECHARGE command. To follow a WRITE the WRITE burst, tWR should be met as shown in WRITE to PRECHARGE figure. Data for any WRITE burst can not be truncated by a subsequent PRECHARGE command.
256M GDDR3 SDRAM
/CK CK CKE HIGH
/CS
/RAS
/CAS
/WE
A0-A7, A9
CA
A10, A11 EN AP A8 DIS AP BA0,1 BA
CA = Column Address BA = Bank Address EN AP = Enable Auto Precharge DIS AP = Disable Auto Precharge DON'T CARE
WRITE Command
- 31 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
WRITE Burst
T0 /CK CK COMMAND WRITE Bank a, Col b NOP NOP NOP NOP T1 T2 T3 T3n T4
256M GDDR3 SDRAM
T4n
T5
T5n
T6
NOP
NOP
ADDRESS
tDQSS(NOM) WDQS
tDQSS
DQ
DI b
DI b
DI b
DI b
DM
tDQSS(MIN) WDQS
tDQSS
DQ
DI b
DI b
DI b
DI b
DM
tDQSS(MAX) WDQS
tDQSS
DQ
DI b
DI b
DI b
DI b
DM
DON'T CARE NOTE :
TRANSITIONING DATA
1. DI b = data-in for column b. 2. Three subsequent elements of data-in are applied in the programmed order following DI b. 3. A burst of 4 is shown. 4. A8 is LOW with the WRITE command (auto precharge is disabled). 5. Write latency is set to 4
- 32 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Consecutive WRITE to WRITE
T0 CK# CK T1 T2 T3 T3n T4 T4n
256M GDDR3 SDRAM
T5
T5n
T6
T6n
T7
COMMAND
WRITE
NOP
WRITE
NOP
NOP
NOP
NOP
NOP
ADDRESS
Bank Col b tDQSS (NOM)
Bank Col n
WDQS
DQ
DI b
DI b
DI b
DI b
DI n
DI n
DI n
DI n
DM
DON'T CARE
TRANSITIONING DATA
NOTE :
1. DI b, etc. = data-in for column b, etc. 2. Three subsequent elements of data-in are applied in the programmed order following DI b. 3. Three subsequent elements of data-in are applied in the programmed order following DI n. 4. Burst of 4 is shown. 5. Each WRITE command may be to any bank of the same device. 6. Write latency is set to 3
- 33 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Nonconsecutive WRITE to WRITE
T0 /CK CK T1 T2 T3 T3n T4 T4n
256M GDDR3 SDRAM
T5
T5n
T6
T6n
T7
COMMAND
WRITE
NOP
NOP
WRITE
NOP
NOP
NOP
NOP
ADDRESS
Bank, Col b
Bank, Col n
tDQSS (NOM) WDQS
DQ
DI b
DI DI DI DON'T CARE b b b
DI n
DI n
DI n
DM
DON'T CARE
TRANSITIONING DATA
NOTE :
1. DI b, etc. = data-in for column b, etc. 2. Three subsequent elements of data-in are applied in the programmed order following DI b. 3. Three subsequent elements of data-in are applied in the programmed order following DI n. 4. burst of 4 is shown. 5. Each WRITE command may be to any bank. 6. Write latency is set to 3
- 34 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
Random WRITE Cycles
T0 /CK CK T1 T2 T3 T3n T4 T4n
256M GDDR3 SDRAM
T5
T5n
T6
T6n
T7
COMMAND
WRITE
NOP
WRITE
NOP
WRITE
NOP
NOP
NOP
ADDRESS
Bank Col b tDQSS (NOM)
Bank Col x
Bank Col g
WDQS
DQ
DI b
DI b
DI b
DI b
DI x
DI x
DI x
DI x
DI g
DI g
DM
DON'T CARE
TRANSITIONING DATA
NOTE :
1. DI b, etc. = data-in for column b, etc. 2. b: etc. = the next data - in following DI b. etc., according to the programmed burst order. 3. Programmed burst length = 4 cases shown. 4. Each WRITE command may be to any bank. 5. Last write command will have the rest of the nibble on T8 and T8n 6. Write latency is set to 3
- 35 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
WRITE to READ
T0 /CK CK T1 T2 T3 T3n T4 T4n T5
256M GDDR3 SDRAM
T6
T10
T18
T19
T19n


COMMAND
WRITE
NOP
WRITE
NOP
NOP
NOP
NOP
READ
NOP
NOP
ADDRESS
Bank Col b
Bank Col b tCDLR = 5
Bank a. Col n
tDQSS (NOM) WDQS
tDQSS
CL = 9
DQ
DI b
DI n
DM
RDQS
tDQSS (MIN) WDQS
tDQSS
CL = 9


DQ
DI b
DI n
DM
RDQS
tDQSS (MAX) WDQS
tDQSS
CL = 9


DQ
DI b
DI n
DM
RDQS
NOTE :
DON'T CARE TRANSITIONING DATA 1. DI b = data-in for column b. 2. Three subsequent elements of data-in the programmed order following DI b. 3. A burst of 4 is shown. 4. tCDLR is referenced from the first positive CK edge after the last data-in pair. 5. The READ and WRITE commands are to the same device. However, the READ and WRITE commands may be to different devices, in which case tCDLR is not required and the READ command could be applied earlier. 6. A8 is LOW with the WRITE command (auto precharge is disabled). 7. WRITE latency is set to 3
- 36 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
WRITE to PRECHARGE
T0 /CK CK T1 T2 T3 T3n T4 T4n T5
256M GDDR3 SDRAM
T11
T12
T13
T14

COMMAND
WRITE
NOP
WRITE
NOP
NOP
NOP
NOP tWR
PRE
NOP tRP
NOP
ADDRESS
Bank Col b
Bank Col b
Bank
tDQSS (NOM) WDQS
tDQSS

DQ
DI b
DM
tDQSS (MIN) WDQS
tDQSS

DQ
DI b
DM
tDQSS (MAX) WDQS
tDQSS

DQ
DI b
DM
DON'T CARE NOTE : 1. DI b = data-in for column b. 2. Three subsequent elements of data-in the programmed order following DI b. 3. A burst of 4 is shown. 4. A8 is LOW with the WRITE command (auto precharge is disabled). 5. WRITE latency is set to 3
TRANSITIONING DATA
- 37 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
PRECHARGE
256M GDDR3 SDRAM
/CK
The PRECHARGE command is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) will be available for a subsequent row access some specified time (tRP) after the PRECHARGE command is issued. Input A8 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. When all banks are to be precharged, inputs BA0, BA1 are treated as "Don't Care." Once a bank has been precharged, it is in the idle state and must be activated prior to any READ or WRITE commands being issued to the bank.
CK CKE HIGH
/CS
/RAS
POWER-DOWN (CKE NOT ACTIVE)
Unlike SDRAMs,GDDR3(x32) SDRAM requires CKE to be active at all times an access is in progress; from the issuing of a READ or WRITE command until completion of the burst. For READs, a burst completion is defined when the Read Postamble is satisfied; For WRITEs, a burst completion is defined BL/2 cycles after the Write Postamble is satisfied. Power-down is entered when CKE is registered LOW. If power-down occurs when there is a row active in any bank, this mode is referred to as active power-down. Entering power-down deactivates the input and output buffers, excluding CK,/CK and CKE. For maximum power savings, the user has the option of disabling the DLL prior to entering powerdown. However, power-down duration is limited by the refresh requirements of the device, so in most applications,the self-refresh mode is preferred over the DLL-disabled power-down mode. When in power-down, CKE LOW and a stable clock signal must be maintained at the inputs of the GDDR3 SDRAM, while all other input signals are "Don't Care." The power-down state is synchronously exited when CKE is registered HIGH (in conjunction with a NOP or DESELECT command). A valid executable command may be applied six clock cycle later.
/CAS
/WE
A0-A7, A9-A11 ALL BANKS A8 ONE BANK BA0,1 BA DON'T CARE BA=Bank Address (if A8 is LOW; otherwise "Don't Care")
PRECHARGE Command
Power-Down
T0 /CK CK CKE tIS tIS tPDEX T1 T2 Ta0 Ta1 Ta2 Ta7
COMMAND
VALID No PEAD/WRITE access in progress
NOP
NOP
NOP
NOP
VALID
Enter power - down mode
Exit power - down mode
- 38 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
TRUTH TABLE - Clock Enable (CKE)
CKEn-1 L CKEn L Self Refresh Power-Down L H Self Refresh All Banks Idle H L Bank(s) Active All Banks Idle DESELECT or NOP DESELECT or NOP DESELECT or NOP AUTO REFRESH X DESELECT or NOP CURRENT STATE Power-Down COMMANDn X
256M GDDR3 SDRAM
ACTIONn Maintain Power-Down Maintain Self Refresh Exit Power-Down Exit Self Refresh Precharge Power-Down Entry Active Power-Down Entry Self Refresh Entry
NOTES
5
NOTES : 1. CKEn is the logic state of CKE at clock edge n; CKEn-1was the state of CKE at the previous clock edge. 2. Current state is the state of the DDR2(x32) immediately prior to clock edge n. 3. COMMANDn is the command registered at clock edge n, and ACTIONn is a result of COMMANDn 4. All state and sequence not shown are illegal or reserved. 5. DESELECT or NOP commands should be issued on any clock edges occurring during the tXSA period.
- 39 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
CURRENT STATE /CS H Any L X L Idle L L L Row Active L L Read (Auto-Precharge Disable) L L L L L L H L H H L H H L L H L L H L L H L L H L L H L L L L H L L L H L H AUTO REFRESH LOAD MODE REGISTER /RAS /CAS X H H L X H L H /WE X H H H
256M GDDR3 SDRAM
COMMAND/ ACTION DESELECT (NOP/ continue previous operation) NO OPERATION (NOP/continue previous operation) DATA TERMINATOR DISABLE ACTIVE (Select and activate row) 7 7 10 10 8 10 10, 12 8 10, 11 10 8, 11 NOTES 13
TRUTH TABLE - CURRENT STATE BANK n - COMMAND TO BANK n
READ (Select column and start READ burst) WRITE (Select Column and start WRITE burst) PRECHARGE (Deactivate row in bank or banks) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE (Only after the READ burst is complete) READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE (Only after the WRITE burst is complete)
Write (Auto-Precharge Disabled)
NOTES : 1. This table applies when CKEn-1 was HIGH and CKEn is HIGH (see CKE Truth Table) and after tXSNR has been met (if the previous state was self refresh). 2. This table is bank-specific, except where noted (i.e., the current state is for a specific bank and the commands shown are those allowed to be issued to that bank when in that state). Exceptions are covered in the notes below. 3. Current state definitions : Idle : The bank has been precharged, and tRP has been met. Row Active : A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read : A READ burst has been initiated, with auto precharge disabled. Write : A WRITE burst has been initiated, with auto precharge disabled. 4. The following states must not be interrupted by a command issued to the same bank. COMMAND INHIBIT or NOP commands, or allowable commands to the other bank should be issued on any clock edge occurring during these states. Allowable commands to the other bank are determined by its current state and truth table- current state bank n command to bank n. and according to truth table - current state bank n -command to bank m. Precharging : Starts with registration of a PRECHARGE command and ends when tRP is met. Once tRP is met, the bank will be in the idle state. Row Activating : Starts with registration of an ACTIVE command and ends when tRCD is met. Once tRCD is met, the bank will be in the :row active" state. - 40 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
256M GDDR3 SDRAM
Read w/ Auto- : Starts with registration of an READ command with auto precharge enabled and ends Precharge Enabled when tRP has been met. Once tRP is met, the bank will be in the idle state. Write w/ Auto- : Starts with registration of a WRITE command with auto precharge enabled and ends Precharge Enabled when tRP has been met. Once tRP is met, the bank will be in the idle state. 5. The following states must not be interrupted by any executable command ; COMMAND INHIBIT or NOP commands must be applied on each positive clock edge during these states. Refreshing : Starts with registration of an AUTO REFRESH command and ends when tRC is met. Once tRC is met, the DDR2(x32) will be in the all banks idle state. Accessing Mode : Starts with registration of a LOAD MODE REGISTER command and ends when tMRD Register has been met. Once tMRD is met, the GDDR3(x32) SDRAM will be in the all banks idle state. Precharge All : Starts with registration of a PRECHARGE ALL command and ends when tRP is met. Once tRP is met, all banks will be in the idle state. READ or WRITE : Starts with registration of the ACTIVE command and ends the last valid data nibble. 6. All states and sequences not shown are illegal or reserved. 7. Not bank-specific; requires that all banks are idle, and bursts are not in progress. 8. May or may not be bank-specific ; If multiple banks are to be precharged, each must be in a valid state for precharging. 9. Left blank 10. READs or WRITEs listed in the Command/Action column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled. 11. Requires appropriate DM masking. 12. A WRITE command may be applied after the completion of the READ burst. 13. Except data termination disable.
- 41 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
256M GDDR3 SDRAM
TRUTH TABLE - CURRENT STATE BANK n - COMMAND TO BANK m
CURRENT STATE /CS H Any L X Idle X L Row Activating, Active, or Prechrging L L L L Read (Auto-Precharge Disable) L L L L Write (Auto-Precharge Disabled) L L L L Read (With Auto-Precharge) L L L L Write (With Auto-Precharge) L L L /RAS /CAS X H H X L H H L L H H L L H H L L H H L L H H L X H L X H L L H H L L H H L L H H L L H H L L H /WE X H H X H H L L H H L L H H L L H H L L H H L L COMMAND/ ACTION DESELECT (NOP/ continue previous operation) NO OPERATION (NOP/continue previous operation) DATA TERMINATOR DISABLE Any Command Otherwise Allowed to Bank m ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select Column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE 6 6 6 6 6, 7 6 6 6 6 6 NOTES 8
NOTES : 1. This table applies when CKEn-1 was HIGH and CKEn is HIGH (see TRUTH TABLE- CKE ) and after tXSNR has been met (if the previous state was self refresh). 2. This table describes alternate bank operation, except where noted (i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m, assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below.
- 42 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
3. Current state definitions : Idle : The bank has been precharged, and tRP has been met.
256M GDDR3 SDRAM
Row Active : A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read : A READ burst has been initiated, with auto precharge disabled. Write : A WRITE burst has been initiated, with auto precharge disabled. Read w/ Auto- : See following text Precharge Enabled Write w/ Auto- : See following text Precharge Enabled 3a. The read with auto precharge enabled or write with auto precharge enabled states can each be broken into two parts : the access period and the precharge period. For read with auto precharge, the precharge period is defined as if the same burst was executed with auto precharge disabled and then followed with the earliest possible PRECHARGE command that still accesses all of the data in the burst. For write with auto precharge, the precharge period begins when tWR ends, with tWR command and ends where the precharge period (or tRP) begins. During the precharge period of the read with auto precharge enabled or write with auto precharge enabled states, ACTIVE, PRECHARGE, READ and WRITE commands to the other bank may be applied. In either case, all other related Limitations apply (e.g., contention between read data write data must be avoided). 3b. The minimum delay from a READ or WRITE command with auto precharge enabled, to a command to a different bank is summarized below.
From Command To Command READ or READ w/AP WRITE or WRITE w/AP WRITE w/AP PRECHARGE ACTIVE READ or READ w/AP WRITE or WRITE w/AP READ w/AP PRECHARGE ACTIVE 1 tCK 1 tCK 1 tCK 1 tCK (BL/2) * tCK [CLRU + (BL/2)] + 1 - WL * tCK Minimum delay (with concurrent auto precharge) [WL + (BL/2)] tCK + tCDLR (BL/2) * tCK
4. AUTO REFRESH and LOAD MODE REGISTER commands may only be issued when all banks are idle. 5. All states and sequences not shown are illegal or reserved. 6. READs or WRITEs listed in the Command/Action column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled. 7. Requires appropriate DM masking. 8. Except data termination disable
- 43 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
ABSOLUTE MAXIMUM RATINGS
Parameter Voltage on any pin relative to Vss Voltage on VDD supply relative to Vss Voltage on VDDQ supply relative to Vss MAX Junction Temperature Storage temperature Power dissipation Short Circuit Output Current Symbol VIN, VOUT VDD VDDQ TJ TSTG PD IOS
256M GDDR3 SDRAM
Value -0.5 ~ VDDQ + 0.5V -0.5 ~ 2.5 -0.5 ~ 2.5 +125 -55 ~ +150 TBD 50
Unit V V V C C W mA
Note : Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure periods may affect reliability.
POWER & DC OPERATING CONDITIONS
Recommended operating conditions (Voltage referenced to 0C Tc 85C ; VDD=2.0V + 0.1V, VDDQ=2.0V + 0.1V)
Parameter
Device Supply voltage Output Supply voltage Reference voltage DC Input logic high voltage DC Input logic low voltage Output logic low voltage AC Input logic high voltage AC Input logic low voltage Input leakage current Any input 0V-Symbol
VDD VDDQ VREF VIH (DC) VIL (DC) VOL(DC) VIH(AC) VIL(AC) II
Min
1.9 1.9 0.69*VDDQ VREF+0.15 VREF+0.25 -5
Typ
2.0 2.0 -
Max
2.1 2.1 0.71*VDDQ VREF-0.15 0.76 VREF-0.25 5
Unit
V V V V V V V V uA
Note
1 1 3 4 4
4,5,6 4,5,6
IIOZ
-5
-
5
uA
Note : 1.Under all conditions, VDDQ must be less than or equal to VDD. 3. VREF is expected to equal 70% of VDDQ for the transmitting device and to track variations in the DC level of the same. Peak-to-peak noise on VREF may not exceed + 2 percent of the DC value. Thus, from 70% of VDDQ, VREF is allowed + 25mV for DC error and an additional +25mV for AC noise. 4. The DC values define where the input slew rate requirements are imposed, and the input signal must not violate these levels in order to maintain a valid level. The inputs require the AC value to be achieved during signal transition edge and the driver should achieve the same slew rate through the AC values. 5. Input and output slew rate =3V/ns. If the input slew rate is less than 3V/ns, input timing may be compromised. All slew rate are measured between Vih and Vil. DQ and DM input slew rate must not deviate from DQS by more than 10%. If the DQ,DM and DQS slew rate is less than 3V/ns, timing is longer than referenced to the mid-point but to the VIL(AC) maximum and VIH(AC) minimum points. 6. VIH overshoot : VIH(max) = VDDQ + 0.5V for a pulse width 500ps and the pulse width can not be greater than 1/3 of the cycle rate. VIL undershoot : VIL(min)=0.0V for a pulse width 500ps and the pulse width can not be greater than 1/3 of the cycle rate.
- 44 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
CLOCK INPUT OPERATING CONDITIONS
256M GDDR3 SDRAM
Recommended operating conditions (0C Tc 85C ; VDD=2.0V + 0.1V, VDDQ=2.0V + 0.1V)
Parameter/ Condition Clock Input Mid-Point Voltage ; CK and /CK Clock Input Voltage Level; CK and /CK Clock Input Differential Voltage ; CK and /CK Clock Input Differential Voltage ; CK and /CK Clock Input Crossing Point Voltage ; CK and /CK Symbol VMP(DC) VIN(DC) VID(DC) VID(AC) VIX(AC) Min 1.16 0.42 0.22 0.22 VREF - 0.15 Max 1.36 VDDQ + 0.3 VDDQ + 0.5 VDDQ + 0.3 VREF + 0.15 Unit Note V V V V V 1,2,3 2 2,4 4 3
Note : 1. This provides a minimum of 1.16V to a maximum of 1.36V, and is always 70% of VDDQ 2. For AC operations, all DC clock requirements must be satisfied as well. 3. The value of VIX is expected to equal 70% VDDQ for the transmitting device and must track variations in the DC level of the same. 4. VID is the magnitude of the difference between the input level in CK and the input level on /CK. 5. The CK and /CK input reference level (for timing referenced to CK and /CK) is the point at which CK and /CK cross; the input reference level for signals other than CK and /CK is VREF. 6. CK and /CK input slew rate must be > 3V/ns
1.26V VREF VDDQ
60
GDDR3
Z0=60
240 10pf
ZQ
Output Load Circuit
Note : 1 . Outputs measured into equivalent load of 10pf at a driver impedance of 40 .
- 45 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
DC CHARACTERISTICS
(Recommended operating conditions unless otherwise noted, 0C Tc 85C )
256M GDDR3 SDRAM
Version Parameter Symbol Test Condition -14 Operating Current (One Bank Active) Precharge Standby Current in Power-down mode Precharge Standby Current in Non Power-down mode Active Standby Current power-down mode Active Standby Current in in Non Power-down mode Operating Current ( Burst Mode)
Burst Length=4 tRC tRC(min). IOL=0mA, tCC= tCC(min). DQ,DM,DQS inputs changing twice per clock cycle. Address and control inputs changing once per clock cycle CKE VIL(max), tCC= tCC(min) CKE VIH(min), CS VIH(min),tCC= tCC(min) Address and control inputs changing once per clock cycle CKE VIL(max), tCC= tCC(min) CKE VIH(min), CS VIH(min), tCC= tCC(min) DQ,DM,DQS inputs changing twice per clock cycle. Address and control inputs changing once per clock cycle IOL=0mA ,tCC= tCC(min), Page Burst, All Banks activated. DQ,DM,DQS inputs changing twice per clock cycle. Address and control inputs changing once per clock.
Unit -15 -16 -20
ICC1
505
500
495
485
mA
ICC2P
140
140
135
130
mA
ICC2N
220
215
200
185
mA
ICC3P
175
170
160
145
mA
ICC3N
385
380
350
265
mA
ICC4
940
935
865
750
mA
Refresh Current Self Refresh Current
ICC5 -GC ICC6 -GL
tRC tRFC
CKE 0.2V Burst Length=4 tRC tRC(min). IOL=0mA, tCC= tCC(min). DQ,DM,DQS inputs changing twice per clock cycle. Address and control inputs changing once per clock cycle
440
435 20
420
390
mA mA mA
5
Operating Current (4Bank interleaving)
ICC7
1060
1055
970
950
mA
Note : 1. Measured with outputs open and ODT off 2. Refresh period is 32ms 3. Measured current at VDD & VDDQ = 2.0V
CAPACITANCE (VDD=2.0V, TA= 25C, f=1MHz)
Parameter
Input capacitance ( CK, CK ) Input capacitance (A0~A11, BA0~BA1) Input capacitance ( CKE, CS, RAS,CAS, WE ) Data & DQS input/output capacitance(DQ0~DQ31) Input capacitance(DM0 ~ DM3)
Symbol
CIN1 CIN2 CIN3 COUT CIN4
Min
2.0 2.0 2.0 3.5 3.5
Max
3.0 3.0 3.0 4.5 4.5
Unit
pF pF pF pF pF
- 46 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
AC CHARACTERISTICS - I
Parameter DQS out access time from CK CK high-level width CK low-level width CK cycle time WRITE Latency DQ and DM input hold time relative to DQS DQ and DM input setup time relative to DQS Active termination setup time Active termination hold time DQS input high pulse width DQS input low pulse widthl Data strobe edge to Dout edge DQS read preamble DQS read postamble Write command to first DQS latching transition DQS write preamble DQS write preamble setup time DQS write postamble Half strobe period CL=9 CL=8 CL=7 tWL tDH tDS tATS tATH tDQSH tDQSL tDQSQ tRPRE tRPST tDQSS tWPRE tWPRES tWPST tHP tQH Symbol tDQSCK tCH tCL tCK -14 Min -0.26 0.45 0.45 1.4 5 0.18 0.18 10 10 0.48 0.48 0.4 0.4 0.4 0 0.4 tCLmin or tCHmin tHP-0.16 -0.3 -0.3 0.35 0.35 1.0 Max +0.26 0.55 0.55 3.3 0.52 0.52 0.160 0.6 0.6 0.6 0.6 Min -0.26 0.45 0.45 1.4 5 0.18 0.18 10 10 0.48 0.48 0.4 0.4 0.4 0 0.4 tCLmin or tCHmin tHP-0.16 -0.3 -0.3 0.35 0.35 1.0 -15 Max +0.26 0.55 0.55 3.3 0.52 0.52 0.160 0.6 0.6 0.6 0.6 -
256M GDDR3 SDRAM
-16 Min -0.29 0.45 0.45 1.6 5 0.20 0.20 10 10 0.48 0.48 0.4 0.4 0.4 0 0.4 tCLmin or tCHmin tHP-0.18 -0.3 -0.3 0.4 0.4 1.1 Max +0.29 0.55 0.55 3.3 0.52 0.52 0.180 0.6 0.6 0.6 0.6 Min -0.35 0.45 0.45 2.0 4 0.25 0.25 10 10 0.48 0.48 0.4 0.4 0.4 0 0.4 tCLmin or tCHmin tHP0.225 -0.3 -0.3 0.5 0.5 1.3 -20 Max +0.35 0.55 0.55 3.3 0.52 0.52 0.225 0.6 0.6 0.6 0.6 -
Unit ns tCK tCK ns ns ns tCK ns ns ns ns tCK tCK ns tCK tCK tCK tCK ns tCK tCK
Note
1
WL-0.2 WL+0.2 WL-0.2 WL+0.2 WL-0.2 WL+0.2 WL-0.2 WL+0.2
2 3
Data output hold time from DQS
-
-
-
-
ns ns ns ns ns ns 4 4
Data-out high-impedance window from CK and /CK tHZ Data-out low-impedance window from CK and /CK tLZ Address and control input hold time Address and control input setup time Address and control input pulse width tIH tIS tIPW
Note : 1. The WRITE latency can be set from 1 to 7 clocks. When the WRITE latency is set to 1 or 2 or 3 clocks(this case can be used regardless of fre quency), the input buffers are turned on during the ACTIVE commands reducing the latency but added power. When the WRITE latency is set to 4 ~7 clocks , the input buffers are turned on during the WRITE commands for lower power operation. The WRITE latency which is over 4 clocks can be used only in case that Write Latency*tCK is greater than 7ns. 2. A low to high transition on the WDQS line is not allowed in the half clock prior to the write preamble. 3. The last rising edge of WDQS after the write postamble must be riven high by the controller. WDQS can not be pulled high by the on-die termination alone. 4. tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referenced to a specific voltage level, but specify when the device output is no longer driving (HZ) or begins driving (LZ).
- 47 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
AC CHARACTERISTICS - II
Parameter Row active time Row cycle time Refresh row cycle time RAS to CAS delay for Read RAS to CAS delay for Write Row precharge time Row active to Row active Last data in to Row precharge @ Normal precharge Last data in to Read command Mode register set cycle time Exit self refresh to Read command Power-down exit time Refresh interval time Symbol tRAS tRC tRFC tRCDR tRCDW tRP tRRD tWR -14 Min 22 31 39 10 6 9 8 9 7 5 6 18 20000 6tCK +tIS 7.8 Max 100K Min 22 31 39 10 6 9 8 9 7 5 6 18 20000 6tCK +tIS 7.8 -15 Max 100K Min 19 27 33 9 5 8 7 8 7 4 5 16
256M GDDR3 SDRAM
-16 Max 100K Min 15 21 27 7 4 6 5 7 7 7.8 3 4 13 20000 4tCK +tIS 7.8 -20 Max 100K Unit tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK us Note
Last data in to Row precharge @ Auto precharge tWR_A tCDLR tMRD tXSR tPDEX tREF
Auto precharge write recovery time + Precharge tDAL
20000 6tCK +tIS -
- 48 -
Rev 1.8 (Apr. 2005)
K4J55323QF-GC
PACKAGE DIMENSIONS (FBGA)
A1 INDEX MARK
256M GDDR3 SDRAM
12.0
12.0

0.8x11=8.8
0.10 Max A1 INDEX MARK
0.8
B C D E F G H J K L M N 13 12 11 10 9 8 7 6 5 4 3 2
0.8
0.8x11=8.8
0.45 0.05
0.40
0.35 0.05 1.40 Max
0.40

Unit : mm
- 49 -
Rev 1.8 (Apr. 2005)


▲Up To Search▲   

 
Price & Availability of K4J55323QF-GC20

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X